| Molecular Basis for the Dynamic Strength of the Integrin α4β1/VCAM-1 Interaction Biophysical Journal, Volume 87, Issue 5, 1 November 2004, Pages 3470-3478 Xiaohui Zhang, Susan E. Craig, Hishani Kirby, Martin J. Humphries and Vincent T. Moy Abstract Intercellular adhesion mediated by integrin and vascular cell adhesion molecule-1 (VCAM-1) plays a crucial role in both the rolling and firm attachment of leukocytes onto the vascular endothelium. Essential to the /VCAM-1 interaction is its mechanical strength that allows the complex to resist the large shear forces imposed by the bloodstream. Herein we employed single-molecule dynamic force spectroscopy to investigate the dynamic strength of the /VCAM-1 complex. Our force measurements revealed that the dissociation of the /VCAM-1 complex involves overcoming at least two activation potential barriers: a steep inner barrier and a more elevated outer barrier. The inner barrier grants the complex the tensile strength to withstand large pulling forces (>50pN) and was attributed to the ionic interaction between the chelated Mg ion at the N-terminal A-domain of the subunit of and the carboxyl group of Asp-40 of VCAM-1 through the use of site-directed mutations. In general, additional mutations within the C-D loop of domain 1 of VCAM-1 suppressed both inner and outer barriers of the /VCAM-1 complex, while a mutation at Asp-143 of domain 2 of VCAM-1 resulted in the suppression of the outer barrier, but not the inner barrier. In contrast, the outer barrier of /VCAM-1 complex was stabilized by integrin activation. Together, these findings provide a molecular explanation for the functionally relevant kinetic properties of the /VCAM-1 interaction. Abstract | Full Text | PDF (389 kb) |
| Minimizing Pulling Geometry Errors in Atomic Force Microscope Single Molecule Force Spectroscopy Biophysical Journal, Volume 95, Issue 8, 15 October 2008, Pages 3991-3998 Monica Rivera, Whasil Lee, Changhong Ke, Piotr E. Marszalek, Daniel G. Cole and Robert L. Clark Abstract In atomic force microscopy-based single molecule force spectroscopy (AFM-SMFS), it is assumed that the pulling angle is negligible and that the force applied to the molecule is equivalent to the force measured by the instrument. Recent studies, however, have indicated that the pulling geometry errors can drastically alter the measured force-extension relationship of molecules. Here we describe a software-based alignment method that repositions the cantilever such that it is located directly above the molecule's substrate attachment site. By aligning the applied force with the measurement axis, the molecule is no longer undergoing combined loading, and the full force can be measured by the cantilever. Simulations and experimental results verify the ability of the alignment program to minimize pulling geometry errors in AFM-SMFS studies. Abstract | Full Text | PDF (1124 kb) |
| Unfolding and Extraction of a Transmembrane α-Helical Peptide: Dynamic Force Spectroscopy and Molecular Dynamics Simulations Biophysical Journal, Volume 89, Issue 5, 1 November 2005, Pages 3129-3140 Sonia Antoranz Contera, Vincent Lemaître, Maurits R.R. de Planque, Anthony Watts and John F. Ryan Abstract An atomic force microscope (AFM) was used to visualize CWALP23 peptides (HN-ACAGAWWLALALALALALALWWA-COO) inserted in gel-phase DPPC and DSPC bilayers. The peptides assemble in stable linear structures and domains. A model for the organization of the peptides is given from AFM images and a 20ns molecular dynamics (MD) simulation. Gold-coated AFM cantilevers were used to extract single peptides from the bilayer through covalent bonding to the cystein residue. Experimental and simulated force curves show two distinct force maxima. In the simulations these two maxima correspond to the extraction of the two pairs of tryptophan residues from the membrane. Unfolding of the peptide precedes extraction of the second distal set of tryptophans. To probe the energies involved, AFM force curves were obtained from 10 to 10nm/s and MD force curves were simulated with 10–10nm/s pulling velocities (). The velocity relationship with the force, , was fitted to two fluctuation adhesive potential models. The first assumes the pulling produces a constant bias in the potential and predicts an ∼ln () relationship. The second takes into account the ramped bias that the linker feels as it is being driven out of the adhesion complex and scales as ∼(ln ). Abstract | Full Text | PDF (610 kb) |
Copyright © 2007 The Biophysical Society. All rights reserved.
Biophysical Journal, Volume 92, Issue 9, L76-L78, 1 May 2007
doi:10.1529/biophysj.107.104901
Biophysical Letters
Changhong Ke, Yong Jiang, Monica Rivera, Robert L. Clark and Piotr E. Marszalek
, 
Address reprint requests and inquiries to Dr. Piotr E. Marszalek.AFM-based single molecule force spectroscopy (AFM-SMFS) has become an important tool to study the elasticity and conformations of nucleic acids, proteins, and polysaccharides 1. In AFM-SMFS, two ends of a molecule are anchored to the substrate and the AFM cantilever tip, respectively. The molecule is mechanically stretched and its length and tension are measured with a subnanometer and picoNewton resolution. Regardless of the method used to anchor the molecule of interest, it is typically and tacitly assumed that the pulling direction is always axial to the extension of the molecule, so that the force applied to the molecule is identical to the force deflecting the AFM cantilever, as illustrated in Figure 1a. However, the actual pulling geometry may be more complicated than the ideal situation in that the attachment point on the substrate may not coincide with the normal projection of the attachment point on the tip, resulting in the molecule being pulled at an angle, as shown in Figure 1b. In such a case, the force measured through the deflection of the AFM cantilever, Fz, is only a component of the force applied to molecule, F. Similarly, the measured extension, Lz, is only the projection of the distance between the two anchor points. It is noted that the other two components of force F can also cause the deflection of the AFM cantilever. Fx can cause the cantilever to deflect either up or down depending on the direction of the moment it generates, while Fy can twist the cantilever laterally. A question about the significance of the errors in force and extension measurements originating from neglecting this “angle effect” was raised by Stuart M. Lindsay some time ago (S. M. Lindsay, private communication, 1998). It appeared that for flexible proteins such as titin, and flexible polysaccharides, such as dextran, which collapse into fairly compact structures, the pulling angle is typically small and such are the errors 3. However, this question has never been addressed for fairly rigid molecules such as double-stranded DNA (dsDNA), collagens, and actin filaments, for which it is likely that the attachment points on the substrate and the AFM tip may be separated by a large distance, resulting in a large pulling angle.
In this letter, we study the effect of pulling geometry on AFM measured force-extension relationships of double-stranded λ-phage DNA, which is a classical subject for force spectroscopy experiments 4,5,6 and displays a very characteristic overstretching transition that is its mechanical signature 5,7,8. We illustrate how the pulling angle affects the force-extension measurements by repeatedly stretching one DNA duplex at various pulling angles and examining the changes in the overstretching transition, and compare the experimental data with theoretical predictions.
A typical force-extension relationship for dsDNA with what is believed to be a minimal pulling angle effect is shown in Fig. 2. We simply approximate its entropic regime by two straight lines. In this model, the molecule is almost fully extended to the length L0, with zero force, and then the force rises linearly with the extension, which reaches L1 when the overstretching transition starts. Then the molecule is overstretched by ∼70%, at a force FBS ≈65 pN; these data originated from optical tweezers measurements, in which the “pulling angle effect” can be controlled to be minimal 5. For modeling purposes we use three linear segments to approximate the force-extension profile from 0 to the end of the B-S transition (L2), which are described by
![]() | (1) |
![]() | (2) |
![]() | (3) |
Measurements of the elasticity of dsDNA were carried out on our custom-made AFM instrument 9,10. This AFM is built around a high precision piezoelectric XYZ stage (Physik Instrumente, Karlsruhe, Germany), which is equipped with three capacitive sensors that provide an open-loop resolution of 0.1nm in the Z axis and 1nm in the X and Y axes. Double-stranded λ-phage DNA digest in a solution of 10mM Tris+HCl, 1mM EDTA, pH 8 was purchased from Sigma (St. Louis, MO). Eighty microliters of DNA solution (60ng/μl) supplemented with 150mM NaCl was deposited onto a freshly-evaporated gold substrate. After the sample was incubated for 2–3h, it was gently rinsed 3–5 times with the buffer solution, and attached to the XYZ stage. Untreated silicon nitride AFM tips (Microlever from Veeco, Woodbury, NY) were employed for the pulling measurements. These cantilevers have a nominal spring constant of 10mN/m and an actual spring constant of ∼20mN/m as measured in solution using the energy equipartition approach 11.
During the pulling experiment, a single dsDNA molecule was identified by recording its characteristic overstretching transition, after which the AFM tip was lifted from the sample surface to avoid extra molecule attachment. The molecule was then stretched repeatedly at different horizontal locations by controlling the motion of the XYZ stage under the AFM tip. A force-extension profile was recorded at each location. If the attachments of the DNA molecule at both the substrate and the AFM cantilever tip are strong, such a measurement can be repeated up to 100 times. We note that although similar effects were observed in several different experiments performed on different DNA molecules, the data shown in this letter was literally obtained on one single DNA duplex that was repeatedly stretched at 51 matrix locations, with a pulling time interval of ∼30s. Three of the experimentally measured force-extension curves are shown in Fig. 3. By determining the plateau forces, defined as the force in the center of the width of the plateau, the location with the highest plateau force (∼90 pN) is identified as the case with a zero or a minimal angle and is designated as position (0,0). This curve is shown in blue in Fig. 3. We note that our maximum plateau force of 90 pN is higher than the 65 pN measured in the experiments using optical tweezers 5. While 65 pN is representative of DNA duplexes carrying single-strand breaks, higher plateau forces have been measured for intact duplexes 12,13. Thus, it is our contention that the pulling experiments conducted in this study were performed on an intact duplex. By fitting the (0,0) curve with the three linear segments described in the previous section, L0 was determined to be 1020nm; L1, 1120nm; and L2, 1820nm. It should be noted that the width of the B-S transition plateau for curve (0,0) is measured to be 700nm, which represents a 68.6% elongation of the molecule length and is in good agreement with the reported data obtained by optical tweezers 5. At location (−400, −800) the width of the B-S transition plateau becomes longer (910nm) and the plateau force becomes smaller (71 pN). As can be seen in Fig. 3, the measured experimental curve for this pulling location (green) is in good agreement with the predicted curve (black). At location (800, −1000), the experimental (red) and predicted (cyan) curves only show a portion of the B-S transition plateau, as the molecule was already under significant tension before pulling occurred. At this location, the width of the B-S transition plateau is 1290nm and the plateau force is 39 pN, as measured from the theoretical curve.
Fig. 4 is a contour plot of the measured plateau forces (FBS) at various pulling locations. It can be clearly seen that, although errors in measured plateau forces related to the measurement locations are minimal for measurements taken at positions close to position (0,0), these errors increase dramatically as the distance from the cantilever to the substrate attachment site becomes larger. As a result, the interpretation of measured force-extension relationships at these locations can be adversely affected.
In this letter, we studied the effect of the pulling geometry on force-extension measurements of dsDNA by AFM-SMFS. The results presented herein indicate that the pulling geometry can significantly alter the measured characteristic curves of single rigid molecules studied with an AFM. As a result, we stress the importance of minimizing the pulling angle in future experiments. A method to minimize pulling angles in AFM-SMFS is currently being investigated and will be reported in a separate publication.
This work was funded by grants from the National Science Foundation and the National Institutes of Health to P.E.M. and R.L.C. M.R. was partially supported by National Science Foundation grant No. DGE-0221632 through an Integrative Graduate Education and Research Traineeship program devoted to biologically inspired materials and material systems.
1. (2000). Stretching single molecules into novel conformations using the atomic force microscope. Nat. Struct. Biol. 7, 719–724. CrossRef | PubMed
2. Reference deleted in proof..
3. (1999). Atomic force microscopy captures length phenotypes in single proteins. Proc. Natl. Acad. Sci. USA 96, 11288–11292. CrossRef | PubMed
4. (2003). Ten years of tension: single-molecule DNA mechanics. Nature 421, 423–427. CrossRef | PubMed
5. (1996). Overstretching B-DNA: the elastic response of individual double-stranded and single-stranded DNA molecules. Science 271, 795–799. PubMed
6. (1999). Sequence-dependent mechanics of single DNA molecules. Nat. Struct. Biol. 6, 346–349. CrossRef | PubMed
7. (1998). DNA under high tension: overstretching, undertwisting, and relaxation dynamics. Phys. Rev. E 57, 2134–2149. PubMed
8. (2001). Effect of pH on the overstretching transition of double-stranded DNA: Evidence of force-induced DNA melting. Biophys. J. 80, 874–881. Abstract | Full Text | PDF (179 kb) | PubMed
9. (2006). Nanospring behavior of ankyrin repeats. Nature 440, 246–249. CrossRef | PubMed
10. (1998). Polysaccharide elasticity governed by chair-boat transitions of the glucopyranose ring. Nature 396, 661–664. CrossRef | PubMed
11. (1995). Sensing specific molecular-interactions with the atomic-force microscope. Biosens. Bioelec. 10, 895–901. PubMed
12. (2000). Mechanical stability of single DNA molecules. Biophys. J. 78, 1997–2007. Abstract | Full Text | PDF (177 kb) | PubMed
13. (1999). Structural transitions of a twisted and stretched DNA molecule. Phys. Rev. Lett. 83, 1066–1069. CrossRef | PubMed